Bldg-New Permit

Permit Type: New Construction Permit

Work Category: 1 or 2 Family Dwellin

PCIS Permit#: 22014-10000-04294

Status: Issued on 10/11/2023

Status Date: 03/04/2015

Work Description:
STE 3100 Non-Structural Interior office tile work includes non-structure includes non-structure.

Address: 12310 1st Helena, Los Angeles, 90049

Property Identifier: Block: 1, Lot: 12, Zone: RS-1

Assessor Information: Book: 7449, Page: 14, Parcel:

Geo Info:Tract: TR 5462, Census Tract: 2640

Popular Projects Nearby

Fast-track your permit approval process with our specialized expediting services tailored to your needs.

Inspection Activity 3

Fast-track your permit approval process with our specialized expediting services tailored to your needs.

PCIS Permit#: Date:
03/04/2015
Status:
Permit Finaled
Result:
Approved
PCIS Permit#: Date:
03/04/2015
Status:
Permit Finaled
Result:
Approved
PCIS Permit#: Date:
03/04/2015
Status:
Permit Finaled
Result:
Approved
Work Description

New single family dwelling over basement with attached garage

Inspection Activity
Date: 07/20/2016
Type: Insulation
Result: Partial Inspection
Status: Issued
Date: 07/18/2016
Type: Interior/Exterior Lathing
Result: Approved
Status: Issued
Date: 07/21/2016
Type: Insulation
Result: Partial Approval
Status: Issued
Date: 07/28/2016
Type: ELECTRICAL-Rough
Result: Partial Approval
Status: Issued
Date: 08/04/2016
Type: Drywall Nailing
Result: Partial Approval
Status: Issued
Date: 08/01/2016
Type: Verify Sprinkler Sign Off
Result: Approved
Status: Issued
Date: 08/01/2016
Type: BUILDING-Rough-Frame
Result: Partial Approval
Status: Issued
Date: 08/05/2016
Type: Insulation
Result: Insp Scheduled
Status: Issued
Date: 08/08/2016
Type: Interior/Exterior Lathing
Result: Approved
Status: Issued
Date: 08/14/2015
Type: Deputy Reinf. Concrete
Result: Approved
Status: Issued
Date: 02/26/2016
Type: Verify Sprinkler Sign Off
Result: Insp Scheduled
Status: Issued
Date: 01/20/2016
Type: Footing/Foundation/Slab
Result: Not Ready for Inspection
Status: Issued
Date: 01/21/2016
Type: Deputy Reinf. Concrete
Result: Approved
Status: Issued
Date: 03/30/2016
Type: Deputy Reinf. Masonry
Result: Approved
Status: Issued
Date: 12/02/2015
Type: Deputy Reinf. Concrete
Result: Approved
Status: Issued
Date: 10/02/2015
Type: ELECTRICAL-Rough
Result: Insp Scheduled
Status: Issued
Date: 11/20/2015
Type: Deputy Wood Construction
Result: Insp Scheduled
Status: Issued
Date: 01/13/2016
Type: Floor/Roof Diaphrgm/Shear Wall
Result: Partial Approval
Status: Issued
Date: 06/17/2015
Type: Footing/Foundation/Slab
Result: Partial Approval
Status: Issued
Date: 12/10/2015
Type: Verify Sprinkler Sign Off
Result: Not Ready for Inspection
Status: Issued
Date: 09/04/2015
Type: Deputy Reinf. Concrete
Result: Insp Scheduled
Status: Issued
Date: 08/12/2015
Type: Reinforced Concrete Frame
Result: Partial Approval
Status: Issued
Date: 09/02/2015
Type: Deputy Reinf. Concrete
Result: Approved
Status: Issued
Date: 01/13/2016
Type: Deputy Wood Construction
Result: Approved
Status: Issued
Date: 11/03/2015
Type: Footing/Foundation/Slab
Result: Partial Approval
Status: Issued
Date: 09/18/2015
Type: PLUMBING-Rough
Result: Insp Scheduled
Status: Issued
Date: 08/05/2015
Type: Reinforced Concrete Frame
Result: Partial Approval
Status: Issued
Date: 08/05/2015
Type: Reinforced Concrete Frame
Result: Partial Approval
Status: Issued
Date: 07/15/2015
Type: Footing/Foundation/Slab
Result: Partial Approval
Status: Issued
Date: 07/07/2015
Type: Footing/Foundation/Slab
Result: Partial Inspection
Status: Issued
Date: 08/31/2015
Type: Reinforced Concrete Frame
Result: Partial Approval
Status: Issued
Date: 11/19/2015
Type: Floor/Roof Diaphrgm/Shear Wall
Result: Conditional Approval
Status: Issued
Date: 02/29/2016
Type: Floor/Roof Diaphrgm/Shear Wall
Result: Corrections Issued
Status: Issued
Date: 09/02/2015
Type: Reinforced Concrete Frame
Result: Partial Approval
Status: Issued
Date: 12/14/2015
Type: Deputy Drilled-In Anchors
Result: Approved
Status: Issued
Date: 12/10/2015
Type: Rough-Elec/Plmb/HVAC
Result: Partial Approval
Status: Issued
Date: 06/30/2015
Type: PLUMBING-Rough
Result: Partial Approval
Status: Issued
Date: 09/17/2015
Type: Reinforced Concrete Frame
Result: Partial Approval
Status: Issued
Date: 03/09/2016
Type: Verify Sprinkler Sign Off
Result: Not Ready for Inspection
Status: Issued
Date: 10/16/2015
Type: Footing/Foundation/Slab
Result: Insp Scheduled
Status: Issued
Date: 10/02/2015
Type: Footing/Foundation/Slab
Result: Insp Scheduled
Status: Issued
Date: 12/02/2015
Type: Footing/Foundation/Slab
Result: Partial Approval
Status: Issued
Date: 11/20/2015
Type: Footing/Foundation/Slab
Result: Insp Scheduled
Status: Issued
Date: 03/30/2016
Type: Floor/Roof Diaphrgm/Shear Wall
Result: Partial Approval
Status: Issued
Date: 12/10/2015
Type: Green Building Rough
Result: Approved
Status: Issued
Date: 12/10/2015
Type: BUILDING-Rough-Frame
Result: Conditional Approval
Status: Issued
Date: 09/30/2015
Type: Deputy Reinf. Concrete
Result: Conditional Approval
Status: Issued
Date: 09/14/2015
Type: Deputy Reinf. Concrete
Result: Conditional Approval
Status: Issued
Date: 09/14/2015
Type: Deputy Reinf. Concrete
Result: Conditional Approval
Status: Issued
Date: 02/26/2016
Type: Structural Steel Frame
Result: Insp Scheduled
Status: Issued
Date: 12/16/2015
Type: Deputy Wood Construction
Result: Approved
Status: Issued
Date: 12/16/2015
Type: Floor/Roof Diaphrgm/Shear Wall
Result: Partial Approval
Status: Issued
Date: 09/16/2015
Type: Footing/Foundation/Slab
Result: No Access for Inspection
Status: Issued
Date: 09/22/2015
Type: Deputy Reinf. Concrete
Result: Conditional Approval
Status: Issued
Date: 03/09/2016
Type: Structural Steel Frame
Result: Partial Inspection
Status: Issued
Date: 06/30/2015
Type: ELECTRICAL-Rough
Result: Partial Approval
Status: Issued
Date: 12/04/2015
Type: Deputy Reinf. Concrete
Result: Insp Scheduled
Status: Issued
Date: 04/20/2016
Type: Floor/Roof Diaphrgm/Shear Wall
Result: Partial Inspection
Status: Issued
Date: 04/26/2016
Type: Floor/Roof Diaphrgm/Shear Wall
Result: Partial Approval
Status: Issued
Date: 05/05/2016
Type: Wood Frame
Result: Partial Approval
Status: Issued
Date: 05/17/2016
Type: PLUMBING-Rough
Result: Corrections Issued
Status: Issued
Date: 05/23/2016
Type: HVAC-Rough
Result: Approved
Status: Issued
Date: 05/26/2016
Type: Interior/Exterior Lathing
Result: Partial Approval
Status: Issued
Date: 05/31/2016
Type: Sewer
Result: Approved
Status: Issued
Date: 06/07/2016
Type: PLUMBING-Rough
Result: Approved
Status: Issued
Date: 06/15/2016
Type: ELECTRICAL-Rough
Result: Corrections Issued
Status: Issued
Date: 06/27/2016
Type: ELECTRICAL-Rough
Result: Insp Cancelled
Status: Issued
Date: 06/29/2016
Type: ELECTRICAL-Rough
Result: Partial Approval
Status: Issued
Date: 06/29/2016
Type: Special/Order Compliance
Result: Approved
Status: Issued
Date: 06/27/2016
Type: ELECTRICAL-Rough
Result: Insp Cancelled
Status: Issued
Date: 06/29/2016
Type: ELECTRICAL-Rough
Result: Partial Approval
Status: Issued
Date: 06/29/2016
Type: Special/Order Compliance
Result: Approved
Status: Issued
Date: 07/05/2016
Type: Shower Pan
Result: Approved
Status: Issued
Date: 07/11/2016
Type: Verify Sprinkler Sign Off
Result: Partial Approval
Status: Issued
Date: 07/11/2016
Type: BUILDING-Rough-Frame
Result: Partial Approval
Status: Issued
Date: 04/12/2017
Type: Deputy Reinf. Concrete
Result: Approved
Status: Issued
Date: 04/19/2017
Type: Deputy Reinf. Masonry
Result: Approved
Status: Issued
Date: 05/02/2017
Type: Deputy Reinf. Concrete
Result: Conditional Approval
Status: Issued
Date: 05/12/2017
Type: Deputy Reinf. Concrete
Result: Insp Scheduled
Status: Issued
Date: 10/06/2017
Type: PLUMBING-Final
Result: Insp Scheduled
Status: Issued
Date: 10/02/2017
Type: ELECTRICAL-Final
Result: Corrections Issued
Status: Issued
Date: 10/06/2017
Type: ELECTRICAL-Final
Result: Insp Scheduled
Status: Issued
Date: 10/12/2017
Type: PLUMBING-Final
Result: Approved
Status: Issued
Date: 10/12/2017
Type: ELECTRICAL-Final
Result: Corrections Issued
Status: Issued
Date: 10/19/2017
Type: HVAC-Final
Result: Partial Inspection
Status: Issued
Date: 10/19/2017
Type: ELECTRICAL-Final
Result: Corrections Issued
Status: Issued
Date: 10/25/2017
Type: HVAC-Final
Result: Approved
Status: Issued
Date: 10/25/2017
Type: ELECTRICAL-Final
Result: Approved
Status: Issued
Date: 10/25/2017
Type: Service/Power Release
Result: Approved
Status: Issued
Date: 10/26/2017
Type: Grading Verification
Result: OK for CofO
Status: Issued
Date: 10/26/2017
Type: Fire Sprinkler Verification
Result: OK for CofO
Status: Issued
Date: 11/01/2017
Type: Green Building Final
Result: Approved
Status: Issued
Date: 11/08/2017
Type: SGSOV-Seismic Gas S/O Valve
Result: SGSOV Approved
Status: Issued
Date: 11/08/2017
Type: Structural Steel Frame
Result: Approved
Status: Issued
Date: 11/08/2017
Type: Footing/Foundation/Slab
Result: Approved
Status: Issued
Date: 11/08/2017
Type: Final
Result: Partial Inspection
Status: Issued
Date: 11/16/2017
Type: CofO Issuance
Result: CofO in Progress
Status: CofO in Progress
Date: 11/15/2017
Type: Final
Result: OK to Issue CofO
Status: CofO in Progress
Date: 03/14/2018
Type: Inspection
Result: Permit Finaled
Status: CofO Issued
Date: 03/14/2018
Type: Inspection
Result: Permit Finaled
Status: CofO Issued
Date: 03/14/2018
Type: CofO Issuance
Result: CofO Issued
Status: CofO Issued
Permit Expediting Services

Fast-track your permit approval process with our specialized expediting services tailored to your needs.

Request a Quote

Ready to get started? Get a personalized estimate for your project.

Get Your Quote
Contractor Info
TURPIN LEVIN BUILDERS INC

License number: 827748
Type: B
Phone: Speak with a Permit Expert
Location: SHERMAN OAKS, CA

Permit Applicant

Principal: MARK ALLEN TURPIN

Type:

Address: 10960 WILSHIRE BLVD., #1510, LOS ANGELES, CA.

Phone:

Experience: years

Applicant: ANDREW ODOM