Fire Sprinkler Permit

Permit Type: New Construction Permit

Work Category: 1 or 2 Family Dwellin

PCIS Permit#: 22014-10000-04294

Status: Issued on 10/11/2023

Status Date: 03/04/2015

Work Description:
STE 3100 Non-Structural Interior office tile work includes non-structure includes non-structure.

Address: 12310 1st Helena, Los Angeles, 90049

Property Identifier: Block: 1, Lot: 12, Zone: RS-1

Assessor Information: Book: 7449, Page: 14, Parcel:

Geo Info:Tract: TR 5462, Census Tract: 2640

Popular Projects Nearby

Fast-track your permit approval process with our specialized expediting services tailored to your needs.

Inspection Activity 3

Fast-track your permit approval process with our specialized expediting services tailored to your needs.

PCIS Permit#: Date:
03/04/2015
Status:
Permit Finaled
Result:
Approved
PCIS Permit#: Date:
03/04/2015
Status:
Permit Finaled
Result:
Approved
PCIS Permit#: Date:
03/04/2015
Status:
Permit Finaled
Result:
Approved
Work Description

INSTALLATION OF (2) 8" IN-BUILDING BACKFLOW DEVICESM, (2) 750-GPM FIRE

Inspection Activity
Date: 04/03/2017
Type: Special/Order Compliance
Result: Cancelled
Status: Issued
Date: 04/05/2017
Type: Rough
Result: Partial Approval
Status: Issued
Date: 04/03/2017
Type: Rough
Result: Cancelled
Status: Issued
Date: 04/05/2017
Type: Special/Order Compliance
Result: Partial Inspection
Status: Issued
Date: 04/06/2017
Type: Fire Dept Connection Hydro
Result: Insp Cancelled
Status: Issued
Date: 04/10/2017
Type: Weld
Result: Partial Inspection
Status: Issued
Date: 04/17/2017
Type: Weld
Result: Partial Approval
Status: Issued
Date: 04/17/2017
Type: Rough
Result: Partial Inspection
Status: Issued
Date: 05/05/2017
Type: Weld
Result: Insp Scheduled
Status: Issued
Date: 05/18/2017
Type: Weld
Result: Partial Approval
Status: Issued
Date: 06/02/2017
Type: Special/Order Compliance
Result: Insp Scheduled
Status: Issued
Date: 05/31/2017
Type: Special/Order Compliance
Result: Not Ready for Inspection
Status: Issued
Date: 06/16/2017
Type: Weld
Result: Insp Scheduled
Status: Issued
Date: 06/13/2017
Type: Weld
Result: Partial Approval
Status: Issued
Date: 06/26/2017
Type: Standpipe Hydro
Result: Partial Approval
Status: Issued
Date: 06/26/2017
Type: Rough
Result: Partial Approval
Status: Issued
Date: 06/30/2017
Type: Weld
Result: Partial Approval
Status: Issued
Date: 06/29/2017
Type: Weld
Result: Partial Approval
Status: Issued
Date: 10/04/2017
Type: Weld
Result: Partial Approval
Status: Issued
Date: 10/12/2017
Type: Weld
Result: Partial Approval
Status: Issued
Date: 10/11/2017
Type: Rough
Result: Not Ready for Inspection
Status: Issued
Date: 10/10/2017
Type: Rough
Result: Partial Approval
Status: Issued
Date: 10/10/2017
Type: Standpipe Flush
Result: Partial Approval
Status: Issued
Date: 10/11/2017
Type: Underground Hydro
Result: Not Ready for Inspection
Status: Issued
Date: 10/10/2017
Type: Standpipe Hydro
Result: Partial Approval
Status: Issued
Date: 10/11/2017
Type: Underground Flush
Result: Corrections Issued
Status: Issued
Date: 10/16/2017
Type: Standpipe Hydro
Result: Partial Approval
Status: Issued
Date: 10/16/2017
Type: Underground Flush
Result: Approved
Status: Issued
Date: 10/20/2017
Type: Weld
Result: Insp Scheduled
Status: Issued
Date: 10/16/2017
Type: Underground Hydro
Result: Approved
Status: Issued
Date: 10/16/2017
Type: Rough
Result: Partial Approval
Status: Issued
Date: 10/27/2017
Type: Weld
Result: Insp Scheduled
Status: Issued
Date: 04/18/2018
Type: Standpipe Hydro
Result: Partial Approval
Status: Issued
Date: 11/15/2017
Type: Weld
Result: Partial Approval
Status: Issued
Date: 05/04/2018
Type: Rough
Result: Insp Scheduled
Status: Issued
Date: 11/22/2017
Type: Weld
Result: Insp Cancelled
Status: Issued
Date: 05/04/2018
Type: Overhead Hydro
Result: Insp Scheduled
Status: Issued
Date: 11/28/2017
Type: Weld
Result: Partial Approval
Status: Issued
Date: 12/05/2017
Type: Weld
Result: Partial Approval
Status: Issued
Date: 12/08/2017
Type: Rough
Result: Insp Scheduled
Status: Issued
Date: 12/08/2017
Type: Overhead Hydro
Result: Insp Scheduled
Status: Issued
Date: 05/18/2018
Type: Fire Pump Hydro
Result: Insp Scheduled
Status: Issued
Date: 05/18/2018
Type: Rough
Result: Insp Scheduled
Status: Issued
Date: 05/17/2018
Type: Overhead Hydro
Result: Not Ready for Inspection
Status: Issued
Date: 05/18/2018
Type: Overhead Hydro
Result: Insp Scheduled
Status: Issued
Date: 05/17/2018
Type: Rough
Result: Not Ready for Inspection
Status: Issued
Date: 12/12/2017
Type: Weld
Result: Partial Approval
Status: Issued
Date: 12/12/2017
Type: Standpipe Flush
Result: Partial Approval
Status: Issued
Date: 12/20/2017
Type: Weld
Result: Partial Approval
Status: Issued
Date: 05/23/2018
Type: Fire Dept Connection Hydro
Result: Partial Approval
Status: Issued
Date: 05/22/2018
Type: Rough
Result: Insp Cancelled
Status: Issued
Date: 05/23/2018
Type: Rough
Result: Partial Approval
Status: Issued
Date: 05/22/2018
Type: Fire Dept Connection Hydro
Result: Insp Cancelled
Status: Issued
Date: 01/16/2018
Type: Weld
Result: Partial Approval
Status: Issued
Date: 01/22/2018
Type: Weld
Result: Partial Approval
Status: Issued
Date: 06/04/2018
Type: Fire Pump Hydro
Result: Not Ready for Inspection
Status: Issued
Date: 02/08/2018
Type: Weld
Result: Partial Approval
Status: Issued
Date: 02/07/2018
Type: Standpipe Flush
Result: Partial Approval
Status: Issued
Date: 02/07/2018
Type: Standpipe Hydro
Result: Partial Approval
Status: Issued
Date: 02/07/2018
Type: Rough
Result: Partial Approval
Status: Issued
Date: 02/06/2018
Type: Weld
Result: Partial Approval
Status: Issued
Date: 06/12/2018
Type: Standpipe Flush
Result: Partial Approval
Status: Issued
Date: 02/12/2018
Type: Weld
Result: Partial Approval
Status: Issued
Date: 02/15/2018
Type: Weld
Result: Partial Inspection
Status: Issued
Date: 02/22/2018
Type: Weld
Result: Partial Approval
Status: Issued
Date: 03/01/2018
Type: Weld
Result: Partial Approval
Status: Issued
Date: 03/01/2018
Type: Rough
Result: Partial Approval
Status: Issued
Date: 06/22/2018
Type: Standpipe Hydro
Result: Insp Scheduled
Status: Issued
Date: 06/20/2018
Type: Standpipe Hydro
Result: Partial Approval
Status: Issued
Date: 06/20/2018
Type: Rough
Result: Partial Approval
Status: Issued
Date: 06/22/2018
Type: Rough
Result: Insp Scheduled
Status: Issued
Date: 03/08/2018
Type: Standpipe Hydro
Result: Partial Approval
Status: Issued
Date: 03/08/2018
Type: Rough
Result: Partial Approval
Status: Issued
Date: 03/05/2018
Type: Weld
Result: Partial Approval
Status: Issued
Date: 03/09/2018
Type: Weld
Result: Insp Scheduled
Status: Issued
Date: 03/16/2018
Type: Weld
Result: Insp Scheduled
Status: Issued
Date: 06/26/2018
Type: Standpipe Hydro
Result: Approved
Status: Issued
Date: 06/25/2018
Type: Standpipe Hydro
Result: Partial Approval
Status: Issued
Date: 06/25/2018
Type: Rough
Result: Partial Approval
Status: Issued
Date: 08/11/2018
Type: Standpipe Flush
Result: Insp Scheduled
Status: Issued
Date: 08/10/2018
Type: Fire Pump Test
Result: Partial Approval
Status: Issued
Date: 08/10/2018
Type: Fire Pump Test
Result: Partial Approval
Status: Issued
Date: 08/16/2018
Type: Fire Dept Connection Flush
Result: Approved
Status: Issued
Date: 08/18/2018
Type: Standpipe Flush
Result: Pending Review
Status: Issued
Permit Expediting Services

Fast-track your permit approval process with our specialized expediting services tailored to your needs.

Request a Quote

Ready to get started? Get a personalized estimate for your project.

Get Your Quote
Contractor Info
COSCO FIRE PROTECTION INC

License number: 577621
Type: C16
Phone: Speak with a Permit Expert
Location: SAN JUAN CAPISTRANO, CA

Permit Applicant

Principal: BARRY GLEN FIELDING

Type:

Address: 1075 W LAMBERT RD, BREA CA

Phone:

Experience: years

Applicant: ADRIANNA GARCIA