Bldg-New Permit

Permit Type: New Construction Permit

Work Category: 1 or 2 Family Dwellin

PCIS Permit#: 22014-10000-04294

Status: Issued on 10/11/2023

Status Date: 03/04/2015

Work Description:
STE 3100 Non-Structural Interior office tile work includes non-structure includes non-structure.

Address: 12310 1st Helena, Los Angeles, 90049

Property Identifier: Block: 1, Lot: 12, Zone: RS-1

Assessor Information: Book: 7449, Page: 14, Parcel:

Geo Info:Tract: TR 5462, Census Tract: 2640

Popular Projects Nearby

Fast-track your permit approval process with our specialized expediting services tailored to your needs.

Inspection Activity 3

Fast-track your permit approval process with our specialized expediting services tailored to your needs.

PCIS Permit#: Date:
03/04/2015
Status:
Permit Finaled
Result:
Approved
PCIS Permit#: Date:
03/04/2015
Status:
Permit Finaled
Result:
Approved
PCIS Permit#: Date:
03/04/2015
Status:
Permit Finaled
Result:
Approved
Work Description

16 units + 50% per TOC tier one density bonus units for total of 24 u

Inspection Activity
Date: 12/30/2020
Type: Deputy Reinf. Concrete
Result: Insp Scheduled
Status: Issued
Date: 12/31/2020
Type: Reinforced Concrete Frame
Result: Insp Scheduled
Status: Issued
Date: 12/31/2020
Type: Green Building Rough
Result: Insp Scheduled
Status: Issued
Date: 12/31/2020
Type: Verify Sprinkler Sign Off
Result: Insp Scheduled
Status: Issued
Date: 01/04/2021
Type: Reinforced Concrete Frame
Result: Partial Approval
Status: Issued
Date: 08/11/2021
Type: Green Building Rough
Result: Not Ready for Inspection
Status: Issued
Date: 08/11/2021
Type: Verify Sprinkler Sign Off
Result: Not Ready for Inspection
Status: Issued
Date: 01/13/2021
Type: Pre-Inspection
Result: Approved
Status: Issued
Date: 01/12/2021
Type: Deputy Reinf. Concrete
Result: Conditional Approval
Status: Issued
Date: 09/24/2020
Type: Pre-Inspection
Result: Approved
Status: Issued
Date: 01/14/2021
Type: Deputy Reinf. Concrete
Result: Conditional Approval
Status: Issued
Date: 01/13/2021
Type: Reinforced Concrete Frame
Result: Partial Approval
Status: Issued
Date: 01/13/2021
Type: Green Building Rough
Result: Not Ready for Inspection
Status: Issued
Date: 01/13/2021
Type: Verify Sprinkler Sign Off
Result: Not Ready for Inspection
Status: Issued
Date: 09/24/2020
Type: Pre-Inspection
Result: Approved
Status: Issued
Date: 08/11/2021
Type: Wood Frame
Result: Partial Approval
Status: Issued
Date: 10/15/2020
Type: Deputy Reinf. Concrete
Result: Insp Scheduled
Status: Issued
Date: 10/15/2020
Type: Excavation/Setback/Form/Re-Bar
Result: Partial Approval
Status: Issued
Date: 10/15/2020
Type: Footing/Foundation/Slab
Result: Conditional Approval
Status: Issued
Date: 10/14/2020
Type: Excavation/Setback/Form/Re-Bar
Result: Insp Cancelled
Status: Issued
Date: 10/16/2020
Type: Excavation/Setback/Form/Re-Bar
Result: Insp Scheduled
Status: Issued
Date: 10/23/2020
Type: Excavation/Setback/Form/Re-Bar
Result: Partial Approval
Status: Issued
Date: 10/22/2020
Type: Excavation/Setback/Form/Re-Bar
Result: Cancelled
Status: Issued
Date: 10/23/2020
Type: Footing/Foundation/Slab
Result: Partial Approval
Status: Issued
Date: 10/22/2020
Type: Deputy Reinf. Concrete
Result: Approved
Status: Issued
Date: 11/05/2020
Type: Reinforced Masonry Frame
Result: Partial Approval
Status: Issued
Date: 11/05/2020
Type: Verify Sprinkler Sign Off
Result: Not Ready for Inspection
Status: Issued
Date: 11/06/2020
Type: Reinforced Concrete Frame
Result: Partial Approval
Status: Issued
Date: 11/05/2020
Type: Footing/Foundation/Slab
Result: Not Ready for Inspection
Status: Issued
Date: 11/05/2020
Type: Green Building Rough
Result: Not Ready for Inspection
Status: Issued
Date: 11/04/2020
Type: Masonry Wall/Backfill
Result: Cancelled
Status: Issued
Date: 05/04/2021
Type: Floor/Roof Diaphrgm/Shear Wall
Result: Partial Approval
Status: Issued
Date: 11/09/2020
Type: Reinforced Concrete Frame
Result: Cancelled
Status: Issued
Date: 02/09/2021
Type: Wood Frame
Result: Cancelled
Status: Issued
Date: 02/09/2021
Type: Verify Sprinkler Sign Off
Result: Cancelled
Status: Issued
Date: 02/08/2021
Type: Floor/Roof Diaphrgm/Shear Wall
Result: Partial Approval
Status: Issued
Date: 11/20/2020
Type: Green Building Rough
Result: Insp Scheduled
Status: Issued
Date: 11/20/2020
Type: Deputy Reinf. Masonry
Result: Conditional Approval
Status: Issued
Date: 11/20/2020
Type: Reinforced Concrete Frame
Result: Insp Scheduled
Status: Issued
Date: 11/20/2020
Type: Verify Sprinkler Sign Off
Result: Insp Scheduled
Status: Issued
Date: 02/09/2021
Type: Green Building Rough
Result: Cancelled
Status: Issued
Date: 11/23/2020
Type: Pre-Inspection
Result: Partial Approval
Status: Issued
Date: 12/09/2020
Type: Footing/Foundation/Slab
Result: Partial Approval
Status: Issued
Date: 02/24/2021
Type: Special/Order Compliance
Result: Corrections Issued
Status: Issued
Date: 02/25/2021
Type: Floor/Roof Diaphrgm/Shear Wall
Result: Partial Approval
Status: Issued
Date: 08/24/2021
Type: Insulation
Result: Not Ready for Inspection
Status: Issued
Date: 03/18/2021
Type: Floor/Roof Diaphrgm/Shear Wall
Result: Partial Approval
Status: Issued
Date: 04/07/2021
Type: Floor/Roof Diaphrgm/Shear Wall
Result: Partial Approval
Status: Issued
Date: 09/03/2021
Type: Wood Frame
Result: Insp Scheduled
Status: Issued
Date: 09/03/2021
Type: Green Building Rough
Result: Insp Scheduled
Status: Issued
Date: 06/07/2021
Type: Floor/Roof Diaphrgm/Shear Wall
Result: Not Ready for Inspection
Status: Issued
Date: 06/09/2021
Type: Floor/Roof Diaphrgm/Shear Wall
Result: Partial Approval
Status: Issued
Date: 09/03/2021
Type: Insulation
Result: Insp Scheduled
Status: Issued
Date: 09/03/2021
Type: Verify Sprinkler Sign Off
Result: Insp Scheduled
Status: Issued
Date: 09/17/2021
Type: Wood Frame
Result: Insp Scheduled
Status: Issued
Date: 09/17/2021
Type: Green Building Rough
Result: Insp Scheduled
Status: Issued
Date: 09/17/2021
Type: Verify Sprinkler Sign Off
Result: Insp Scheduled
Status: Issued
Date: 09/17/2021
Type: Insulation
Result: Insp Scheduled
Status: Issued
Date: 07/29/2021
Type: Interior/Exterior Lathing
Result: Cancelled
Status: Issued
Date: 07/27/2021
Type: Insulation
Result: Partial Approval
Status: Issued
Date: 07/30/2021
Type: Interior/Exterior Lathing
Result: Partial Approval
Status: Issued
Date: 12/15/2021
Type: Light Gage Steel Frame
Result: Conditional Approval
Status: Issued
Date: 08/06/2021
Type: Deputy Wood Construction
Result: Insp Scheduled
Status: Issued
Date: 09/27/2021
Type: Insulation
Result: Partial Approval
Status: Issued
Date: 09/27/2021
Type: Deputy Wood Construction
Result: Approved
Status: Issued
Date: 09/27/2021
Type: Floor/Roof Diaphrgm/Shear Wall
Result: Partial Approval
Status: Issued
Date: 12/22/2021
Type: Light Gage Steel Frame
Result: Partial Inspection
Status: Issued
Date: 12/21/2021
Type: Light Gage Steel Frame
Result: Not Ready for Inspection
Status: Issued
Date: 10/22/2021
Type: Insulation
Result: Insp Scheduled
Status: Issued
Date: 12/30/2021
Type: Light Gage Steel Frame
Result: Insp Scheduled
Status: Issued
Date: 08/30/2022
Type: Footing/Foundation/Slab
Result: Partial Approval
Status: Issued
Date: 11/09/2021
Type: Green Building Rough
Result: Not Ready for Inspection
Status: Issued
Date: 11/09/2021
Type: Drywall Nailing
Result: Partial Approval
Status: Issued
Date: 12/30/2021
Type: Light Gage Steel Frame
Result: Insp Scheduled
Status: Issued
Date: 11/18/2021
Type: Interior/Exterior Lathing
Result: Approved
Status: Issued
Date: 03/17/2022
Type: Pre-Inspection
Result: Corrections Issued
Status: Issued
Date: 12/30/2021
Type: Light Gage Steel Frame
Result: Insp Scheduled
Status: Issued
Date: 01/28/2022
Type: Drywall Nailing
Result: Insp Scheduled
Status: Issued
Date: 01/28/2022
Type: Green Building Rough
Result: Insp Scheduled
Status: Issued
Date: 02/04/2022
Type: Drywall Nailing
Result: Insp Scheduled
Status: Issued
Date: 02/09/2022
Type: Drywall Nailing
Result: Partial Approval
Status: Issued
Date: 09/20/2022
Type: Footing/Foundation/Slab
Result: Partial Approval
Status: Issued
Date: 07/29/2022
Type: Reinforced Concrete Frame
Result: Insp Scheduled
Status: Issued
Date: 07/29/2022
Type: Final
Result: Insp Scheduled
Status: Issued
Date: 07/29/2022
Type: Verify Sprinkler Sign Off
Result: Insp Scheduled
Status: Issued
Date: 08/18/2022
Type: Footing/Foundation/Slab
Result: Corrections Issued
Status: Issued
Date: 01/24/2023
Type: Special/Order Compliance
Result: Partial Inspection
Status: Issued
Date: 02/17/2023
Type: Final
Result: Insp Scheduled
Status: Issued
Date: 02/17/2023
Type: Wood Frame
Result: Insp Scheduled
Status: Issued
Date: 02/17/2023
Type: Reinforced Concrete Frame
Result: Insp Scheduled
Status: Issued
Date: 02/17/2023
Type: SGSOV-Seismic Gas S/O Valve
Result: Insp Scheduled
Status: Issued
Date: 02/17/2023
Type: Smoke Detectors
Result: Insp Scheduled
Status: Issued
Date: 02/17/2023
Type: Structural Steel Frame
Result: Insp Scheduled
Status: Issued
Date: 02/17/2023
Type: Footing/Foundation/Slab
Result: Insp Scheduled
Status: Issued
Date: 02/17/2023
Type: Verify Sprinkler Sign Off
Result: Insp Scheduled
Status: Issued
Date: 02/17/2023
Type: Fire Sprinkler Verification
Result: OK for CofO
Status: Issued
Date: 02/17/2023
Type: Drywall Nailing
Result: Insp Scheduled
Status: Issued
Date: 02/17/2023
Type: Green Building Final
Result: Insp Scheduled
Status: Issued
Date: 02/17/2023
Type: Reinforced Masonry Frame
Result: Insp Scheduled
Status: Issued
Date: 02/21/2023
Type: Grading Verification
Result: Not Applicable
Status: Issued
Date: 02/21/2023
Type: Heat,Vent,A/C Verification
Result: OK for CofO
Status: Issued
Date: 02/21/2023
Type: Elevator Verification
Result: OK for CofO
Status: Issued
Date: 02/21/2023
Type: AIM Verification
Result: Not Applicable
Status: Issued
Date: 02/21/2023
Type: Plumbing Verification
Result: OK for CofO
Status: Issued
Date: 03/14/2023
Type: Inspection
Result: Permit Finaled
Status: CofO Issued
Date: 03/14/2023
Type: Inspection
Result: Permit Finaled
Status: CofO Issued
Date: 03/14/2023
Type: CofO Issuance
Result: CofO Issued
Status: CofO Issued
Date: 03/14/2023
Type: Inspection
Result: Permit Finaled
Status: CofO Issued
Date: 03/14/2023
Type: Inspection
Result: Permit Finaled
Status: CofO Issued
Date: 03/14/2023
Type: CofO Issuance
Result: CofO Issued
Status: CofO Issued
Permit Expediting Services

Fast-track your permit approval process with our specialized expediting services tailored to your needs.

Request a Quote

Ready to get started? Get a personalized estimate for your project.

Get Your Quote
Contractor Info
IM HOME CONSTRUCTION INC

License number: 867630
Type: B
Phone: Speak with a Permit Expert
Location: SHERMAN OAKS, CA

Permit Applicant

Principal: ITAY MEVORAKH

Type:

Address: 14200 VENTURA BLVD, #106, SHERMAN OAKS, CA

Phone:

Experience: years

Applicant: ITAY MEVORAKH